“ACS Appl. Mater. Interfaces”: An Aerosol-Jet-Printed Graphene Immunosen-sor for Label-Free Cytokine Detection in Serum

Product Introduction

Equipment Parameters

I. Core Research Summary

This work develops a graphene–nitrocellulose‑specific aerosol‑jet printing ink and uses it to directly write high‑precision interdigitated sensor arrays on flexible Kapton polyimide substrates. The graphene surface is then modified via high‑temperature CO₂ annealing to introduce oxygen‑containing functional groups, followed by covalent conjugation of specific antibodies to construct an immunosensor. Comprehensive validation—including electrochemical performance, analysis of biological serum samples, and mechanical stability—has been carried out. The key findings are as follows:

Micrometer-scale, high-precision aerosol graphene interdigital electrode

Single‑channel printing fabricates 40‑μm‑wide graphene electrode fingers with a finger pitch of 100 μm; the resulting thin film is only 25 nm thick, and its electrical conductivity reaches 1×10⁴ to 7×10⁴ S/m—significantly thinner than conventionally screen‑printed or inkjet‑printed thick films, thereby substantially reducing material consumption. The device incorporates a complete set of 50 interdigitated electrode pairs, providing ample effective sensing area and delivering an excellent electrochemical signal‑to‑noise ratio.

CO₂ Annealing-Induced Modification to Construct a Bioactive Graphene Interface

After annealing, the surface of graphene exhibits a 10% increase in carboxyl and carbonyl oxygen-containing functional groups, enabling covalent immobilization of antibodies via EDC/NHS chemistry without the need for complex chemical modifications. The underlying graphene sp² framework remains largely defect-free, simultaneously offering high electrical conductivity and robust bioconjugation capabilities.

Dual-cytokine assay with ultra-wide linear range and ultra-low detection limit

Artificial bovine serum matrix validation:

  • IFN-γ linear range: 0.1–5 ng/mL; limit of detection: 25 pg/mL.
  • The linear range of IL-10 is 0.1–2 ng/mL, with a limit of detection of 46 pg/mL.
  • At the same IL‑6 concentration, with cross‑cytokine interference, signal fluctuations are less than 20, demonstrating excellent specificity; no sample labeling or pre‑concentration is required throughout the entire process.

Excellent flexible mechanical stability

After 250 cycles of bending with a radius of just 5 mm, the electrode resistance variation remains below 1%, and the electrochemical impedance shift is only 6%. Even after immersion in buffer solution, the device maintains stable sensing performance, making it suitable for subcutaneous implantation and wearable monitoring applications.

Rapid Testing Procedure

Sample incubation takes only 30 minutes to achieve quantitative impedance measurements, a significant reduction compared with the several hours required by conventional immunoassays. The maskless aerosol‑based fabrication process enables rapid iteration of multi‑marker sensing chips.

II. Complete Preparation Process Flow and Core Process Advantages of Aerosol Spraying

(1) Complete Graphene IDE Aerosol Printing Process

  • Graphite and nitrocellulose are shear‑exfoliated to prepare a composite powder, which is then formulated into a butyl lactate‑based stable aerosol ink.
  • Ultrasonic atomization of graphene ink, focusing with a nitrogen sheath gas jet, and uniform-speed printing of interdigitated electrode arrays on a 60°C substrate.
  • Air pyrolysis at 350°C is used to remove the binder, yielding a continuous, highly conductive graphene film.
  • At 400°C, CO₂ tube‑type annealing induces the formation of numerous carboxyl functional groups on the graphene surface.
  • After EDC/NHS activation, IFN-γ/IL-10–specific antibodies are immobilized to block non-specific adsorption sites, thereby completing the sensor chip.

(II) Five Core Processes (in comparison with lithography, screen printing, and inkjet printing)

  • Sub-50 μm ultra-high-resolution maskless direct writing

Screen printing achieves a minimum line width of 100 μm, while inkjet typically offers 60 μm lines; AJP, meanwhile, stably produces 40 μm‑scale fine interdigitated electrodes, with extremely small electrode gaps that greatly enhance the electrochemical interface and significantly boost impedance‑sensing sensitivity—without the need for photolithographic masks or cleanroom facilities.

  • Ultra-thin, low-power graphene film formation

A single-layer printed conductive film is only 25 nm thick; for the same sensing area, graphene-based materials require far less material than those used in other printing processes. The resulting thin film is continuous with minimal porosity, and its conductive network remains intact and stable.

  • Compatible with wide-viscosity nano-ink; less prone to clogging.

Graphene‑based composite dispersions can maintain stable atomization over extended periods, addressing the issue of nozzle clogging in piezoelectric inkjet printers when using high‑solid carbon inks, and enabling highly consistent continuous batch printing.

  • Gentle forming on flexible substrates, compatible with PI films.

The printing process employs a low-temperature substrate, eliminating high-temperature baking that could degrade the polyimide base material. The resulting devices exhibit exceptional flexibility, enabling substantial bending and making them well-suited for wearable applications and subcutaneous flexible sensing platforms.

  • Digital rapid-iteration sensor deployment

CAD allows free modification of the number of interdigitated fingers, finger width, and array configuration, enabling rapid prototyping for various cytokines and multiplex assays, thereby reducing the R&D cycle from several days to just a few hours.

III. Five Key Technological Innovations

Innovation 1: The world’s first fully printed graphene interdigitated immunosensing platform for aerosols.

Innovatively employing AJP, a fully fabricated graphene IDE is developed for label-free cytokine detection, bypassing the costly and complex fabrication routes of photolithography and laser‑induced graphene, thereby enabling additive mass production of carbon‑based electrochemical chips.

Innovative New Process for Surface Activation of Graphene via CO₂-Atmosphere Annealing

Without introducing heavy-metal modifications, the number of oxygen-containing active functional groups can be controllably increased solely through atmospheric thermal treatment, while preserving the highly conductive graphite backbone at the substrate level, thereby simultaneously meeting the dual requirements of electrochemical conductivity and covalent immobilization of antibodies.

Innovative 3 Ultra-Thin, High-Sensitivity Interdigital Impedance Sensing Architecture

A 40-μm microelectrode reduces the interelectrode spacing, shortening the diffusion path of redox probes; under the same biomarker concentration, this results in a greater impedance change, enabling stable detection of proteins at the picogram level.

Innovation 4: Bendable, Body-Fluid-Compatible Flexible Immunochip

The aerosol‑derived graphene film exhibits strong adhesion to Kapton substrates, remains intact after repeated bending, and maintains stable signal performance even after prolonged immersion in buffer solutions, making it well suited for long‑term immunological monitoring in subcutaneous implants and skin‑wearable devices.

Innovation 5: Standardized Manufacturing Protocol for Universal Label-Free Immunoassays

By simply replacing the corresponding antibody, it is possible to detect viral proteins, tumor markers, and multiple cytokines, enabling a single aerosol‑based production line to support the development of various POCT diagnostic chips.

IV. Existing Process Challenges and Corresponding Solutions for Overcoming Them

Challenge 1: Traditional printed lines are thick, resulting in insufficient electrochemical sensitivity of the interdigitated electrodes.

✅ Aerosol sheath‑based focusing achieves 40‑μm‑scale fine tips, reducing the electrode gap and enhancing interfacial electron‑transfer efficiency, thereby significantly improving the ability to detect low‑concentration proteins.

Challenge 2: Graphene films lack active functional groups, causing antibodies to desorb easily through physical adsorption.

✅High-temperature CO₂ annealing enables the controlled introduction of carboxyl groups onto the graphene surface, facilitating stable covalent coupling; repeated washing does not result in antibody detachment, thereby enhancing assay reproducibility.

Challenge 3: Carbon-based inks tend to clog the print head, making continuous batch printing impossible.

✅ The aerosol ultrasonic atomization system is compatible with high-solid-content graphene inks, eliminates the clogging issues common to piezoelectric nozzles, and ensures consistently uniform printed patterns over extended printing sessions.

Challenge 4: Most carbon sensing membranes are thick and have high material costs.

✅ Single-layer printing of an ultra-thin 25-nm conductive layer, with graphene deposited precisely at designated locations on demand; large‑area blank substrates eliminate material waste, significantly reducing the cost of mass‑produced test cards.

Challenge 5: Rigid lithographic electrodes cannot be adapted for wearable or subcutaneous flexible monitoring.

✅AJP is fabricated at room temperature on a flexible PI film; after 250 bending cycles, its electrical and sensing performance exhibits minimal degradation, making it well-suited for curved surfaces and implantable bioelectronics.

V. Future Multi-Industry Application Scenarios Scenery

  • Rapid On-Site Screening for Zoonotic Diseases
Flexible lateral flow test strips for on-site detection of paratuberculosis and Mycobacterium tuberculosis in cattle and sheep, delivering results within 30 minutes from minute volumes of bodily fluids, serving as an alternative to laboratory ELISA assays and reducing testing costs for livestock management and disease control.
  • Human autoimmune and tuberculosis home-monitoring patch
Wearable flexible sensing patches enable non-invasive collection of trace bodily fluids and continuous monitoring of the IFN‑γ/IL‑10 ratio, supporting long-term home-based follow-up for chronic diseases.
  • Hospital Multiplex Cytokine Diagnostic Chip
A multi-channel aerosol array chip enables the simultaneous detection of multiple immune biomarkers, rapidly distinguishing between inflammation, infection, and autoimmune disease types.
  • In vitro high-throughput screening of immunological efficacy for new drugs
A sensor array tailored for cell culture in pharmaceutical companies enables real-time monitoring of cytokine secretion levels, significantly reducing the number of animal experiments.
  • Implantable Subcutaneous Long-Acting Immune Monitoring Device
Ultra-thin aerosol‑derived graphene flexible electrodes, implanted subcutaneously for short-term use, enable continuous monitoring of dynamic changes in in vivo immune factors, facilitating postoperative inflammation surveillance.
Image and Text Guide

Figure 1. Schematic illustration of the fabrication and biofunctionalization of AJP‑fabricated graphene IDEs. (a) Schematic showing the formulation of the graphene ink used for aerosol printing. (b) The aerosol jet printing mechanism for graphene ink, illustrating how the sheath gas surrounding the aerosolized graphene‑ink particles focuses the ink to the desired diameter. (c) An AJP‑fabricated graphene IDE deposited on a polyimide (Kapton) substrate. (d) Using the N‑(3‑dimethylaminopropyl)‑N′‑ethylcarbodiimide/N‑hydroxysuccinimide (EDC/NHS) chemistry, selective antibodies targeting IL‑10 or IFN‑γ are immobilized onto the carboxyl‑functionalized graphene surface. (e) The remaining exposed surfaces of the graphene sensor are coated with a blocking agent (a mixture of bovine serum albumin, fish gelatin, and Tween‑20) and incubated together with the antigen.

Figure 2. Optical characterization of the AJP graphene IDE. (a) Optical micrograph showing line resolution; (b) SEM micrograph revealing the surface morphology of a graphene sheet on a polyimide substrate (magnification: 75,000×); (c) Top-view SEM micrograph of an ultrathin film (thickness < 100 nm) printed on silicon dioxide, acquired at a 45° tilt (magnification: 30,000×); (d) Two‑dimensional and three‑dimensional height images illustrating the surface irregularities and roughness of an untreated Kapton film; (e) AFM image of the finger-like structures of the graphene IDE; (f) AFM cross-sectional profile showing that the printed graphene has an average thickness of 25 nm (data extracted from the region within the box in panel e).

Figure 3. Spectral analysis of graphene IDEs. (a) XPS spectrum of the graphene IDE before thermal annealing in carbon dioxide (CO₂). (b) XPS spectrum of the graphene IDE after thermal annealing in carbon dioxide (CO₂). (c) Raman spectra of the printed graphene IDE before and after thermal annealing in carbon dioxide (CO₂), showing the D peak, G peak, and 2D peak.

Figure 4. (a) Analysis of multiple printed lines at a sheath flow rate of 55 sccm, a carrier gas flow rate of 35 sccm, and various printing speeds reveals that both line thickness and line width vary with printing time (s/mm), which is inversely proportional to the printing speed (mm/s). (b) The relationship between the electrical conductivity of graphene lines printed on a Kapton substrate and the maximum film thickness shows that conductivity increases with increasing film thickness, but begins to decline beyond approximately 200 nm. (c) A plot of resistance multiplied by cross-sectional area versus the dimensions of the printed graphene lines (resembling an IDE finger‑like structure) for different numbers of printing passes (labeled 1, 2, 3, 4, 5, 10, 15, 20, 25, and 30 in the legend). The slope of this curve represents the resistivity of the printed graphene. Electrochemical characterization of the graphene IDE includes: (d) cyclic voltammetry (CV) curves obtained at scan rates of 5, 10, 25, 50, and 100 mV/s, before and after CO₂ annealing; (e) Nyquist plots derived from electrochemical impedance spectroscopy (EIS) measurements taken before and after thermal annealing in CO₂; and (f) an enlarged view of the Nyquist plot for the annealed IDE shown in the lower left corner of panel (e), exhibiting the characteristic semicircular Nyquist curve.

Figure 5. (Top) Detection of IFN‑γ and IL‑10 using a graphene‑based IDE sensor. Percentage changes in the charge-transfer resistance (Rct) as a function of (a) IFN‑γ and (b) IL‑10 concentration. Error bars represent the standard deviation of the mean values obtained from three independent biofunctionalized electrodes, each coated with the corresponding bovine monoclonal antibody. (Bottom) (c) Selectivity testing of the IFN‑γ antibody toward IL‑10 and IL‑6 antigens, and (d) selectivity testing of the IL‑10 antibody toward IFN‑γ and IL‑6 antigens.

Figure 6. Bending‑test experiments conducted using the AJP graphene IDE. (a) Photograph of the testing apparatus, showing the IL‑10‑functionalized biosensor being bent around a suspended rod within a 3D‑printed channel filled with PBS solution. (b) Variation of the electrical resistance of the AJP graphene IDE with the number of bending cycles when no biological functionalization has been performed. (c) Relationship between the number of bends of the biosensor around a rod (diameter 5 mm) and the corresponding change in electrical resistance.



Keywords


Download Materials

Related Products Other Achievements Related Videos

Product Inquiry

Submit Message

*Note: Please ensure that all information provided is accurate and that your contact details are up to date, so we can reach you as soon as possible.