Flex A732

Model: Flex A732 Light Source: UV LED (405 nm) Exposure Resolution: 30 µm (key parameter for micro‑ and nano‑fabrication) Layer Thickness: 5–60 µm (adjustable, suitable for diverse structures) Maximum Build Volume: 70 mm × 30 mm × 20 mm (ideal for research samples and small precision parts) Slicing Software: Proprietary, with customizable features; includes real-time slicing preview and 3D microscopic measurement.

Flex A532

Model: Flex C762 Light Source: UV LED (405 nm) Exposure Resolution: 12 µm (key parameter for micro‑ and nano‑fabrication) Layer Thickness: 5–40 µm (adjustable, suitable for diverse structures) Maximum Build Volume: 70 mm × 60 mm × 20 mm (ideal for research samples and small precision parts) Slicing Software: Proprietary, with customizable features; includes real-time slicing preview and 3D microscopic measurement.

Flex C762

Model: Flex C762 Light Source: UV LED (405 nm) Exposure Resolution: 12 µm (key parameter for micro‑ and nano‑fabrication) Layer Thickness: 5–40 µm (adjustable, suitable for multi‑material structures) Maximum Build Volume: 70 mm × 60 mm × 20 mm (ideal for research samples and small precision parts) Slicing Software: Proprietary, with customizable features; includes real-time slicing preview and 3D microscopic measurement.

Flex C831

Model: Flex C831 Light Source: UV LED (405 nm) Exposure Accuracy: 10 µm (key parameter for micro‑ and nano‑fabrication) Layer Thickness: 5–40 µm (adjustable, suitable for diverse structures) Maximum Build Volume: 80 mm × 30 mm × 10 mm (ideal for research samples and small precision parts) Slicing Software: Proprietary, with customizable features; includes real-time slicing preview and 3D microscopic measurement.

Flex Y632

Model: Flex Y632 Light Source: UV LED (405 nm) Exposure Resolution: 2.0 µm (key parameter for micro‑ and nano‑fabrication) Layer Thickness: 5–20 µm (adjustable, suitable for diverse structures) Maximum Build Volume: 60 mm × 30 mm × 20 mm (ideal for research samples and small precision parts) Slicing Software: In‑house developed, with customizable features; includes real-time slicing preview and 3D microscopic measurement capabilities.

Flex Y475

Flex Y475 (1) Overview: (1) Micro‑ and nano‑scale photopolymerization technology: utilizes a 405 nm UV LED light source, delivers 1.9 µm exposure accuracy, and offers adjustable layer thicknesses from 5 to 20 µm, enabling precise fabrication of microfluidic channels, microstructured arrays, and other intricate features—suitable for diverse research and manufacturing applications. (2) Proprietary intelligent slicing system: with independent intellectual property rights, it supports customizable printing strategies, integrates real-time slice previewing, reduces trial-and-error costs in research and prototyping, and accommodates dual-material printing requirements. (3) Closed-loop quality control design: equipped with three-dimensional microscopic measurement capabilities, ensuring consistent and repeatable printed structures, thereby guaranteeing reliable research data and meeting stringent product‑level precision standards. (4) Compatible material systems: microfluidics‑specific resins—including transparent/semi‑transparent resins for visual observation, biocompatible resins, and highly elastic soft resins—cater to varied research and manufacturing needs; ceramic and composite materials such as zirconia and alumina ceramic slurries for high‑temperature/high‑pressure environments, metal pastes for expanded application scopes, and functionalized ceramic materials. (5) Core product advantages: Dual‑material compatibility: one device covers both microfluidic resin and ceramic printing, addressing diverse research and precision‑manufacturing demands without requiring additional equipment. Micro‑ and nano‑scale precision: 1.9 µm exposure accuracy supports cutting‑edge micro‑ and nanoscale research experiments and the development of precision prototypes. Full‑process controllability: closed-loop quality control ensures reproducible research data, consistent structural integrity, and compliance with precision specifications. Customizable adaptation: proprietary software combined with open interfaces allows tailored solutions to meet specific requirements. (6) Application industries and scenarios: 1) Research applications: studies related to micro‑ and nano‑scale fluid flow, interfacial flow, fluid–solid coupling, material properties, novel material development, and biophysical research. 2) Industrial and medical extensions: biomedical applications including microfluidic biochips and precision components for medical devices; precision manufacturing of MEMS, sensors, and fine ceramic parts; research and education settings such as university laboratory projects and experimental teaching. Flex Y745: UV LED light source (405 nm), 1.9 µm exposure accuracy (a core parameter for micro‑ and nano‑scale fabrication), adjustable layer thickness of 5–20 µm to accommodate diverse structural designs, maximum build dimensions of 73 mm × 41 mm × 50 mm suitable for research samples and small precision parts. The slicing software is developed in‑house, supporting custom functions, including real-time slice previewing and three‑dimensional microscopic measurement. Key highlights: micro‑ and nano‑scale fabrication, dual‑material compatibility, empowering both research and precision manufacturing; a professional‑grade, high‑precision photopolymerization 3D printer that simultaneously supports microfluidic resins and ceramic materials, delivering exceptional precision specifically designed for microfluidic chips and ceramic component fabrication—enabling innovations in biomedicine, scientific research, and high‑end manufacturing.

< 1 > proceed page